Line
interactive Design |
 |
Fully
digitalized microprocessor controlled |
 |
Smart
RS232 communication port for power management software |
 |
Tel/modem/fax/Internet
surge suppression |
 |
Boost
and buck AVR |
 |
Hot
swappable battery by user |
 |
Extended
battery time with battery pack |
 |
Surge
protected output for critical load |
 |
Site
wiring faultt indicator |
 |
EMI/RFI
noise filter |
 |
Surge
protection output for critical load |
 |
Overload,
on-line, battery status LED |
 |
Lighting
and surge protection |
 |
Short
circuit an overload protection |
 |
50/60
Hz frequency auto sensing |
 |
Cold
start (DC power on) |
 |
Advanced
battery management (ABM) |
 |
Energy
saving (UPS sleep mode) |
 |
Automatic
charging when UPS off |
 |
History
recording of Power failure events |
 |
Schedule
shut down on reboot |
 |
Backup
online battery status power status display by software |
| Model
|
800AP |
1000AP
|
1200AP |
1500AP |
2200AP |
| Power Rating |
800VA |
1000VA |
1200VA |
1500VA
|
2200VA |
| Input |
| Voltage |
100V,
110V, 120V, 220V, 230V, 240V, +/-25% |
| Frequency |
50Hz
OR 60Hz +/- 5Hz |
| Output |
| Output Capacity |
800VA |
1000VA |
1200VA |
1500VA
|
2200VA |
Voltage Rating
|
100V
/ 110V / 120V / 220V / 230V / 240 Volts (Nominal) |
| Frequency |
50/60
Hz +/- 0.5 Hz with proprietary Quartizile Frequency Correction |
| Voltage Regulation
|
AVR
automatically increases the output voltage 15% above input voltage
if -9% to -25% of nominal. AVR decreases output voltage 13% below
input voltage if +9% to 25% of nominal |
| Waveform |
Modified
sinewave |
| Load Power Factor
|
0.8
lagging |
| Transfer |
Over
Voltage |
Line
to inverter at 125% / Inverter to line 123% |
| Under
Voltage |
Line
to inverter at 75% / Inverter to line 77% |
| Transfer
Time |
Line
to inverter 2 miliseconds / Inverter to line 1 milisecond |
| Indicators |
| AC
Normal |
Green
LED steady on |
| Battery
low |
Yellow
LED flashes |
| Replace
Battery |
Red
lights on |
|
| Alarm |
| Backup
Mode |
Beeping
every 4 secs (about 0.47Hz) |
| Battery
Low |
Beeping
every 1 sec then auto shutdown (about 1.824Hz) |
| Overload |
Continuos
Beeping Sound (about 1.824Hz) |
|
| Interface |
Bi-directional
communication port |
| Protection
and Filtering |
| Spike
Protection |
320
joules, 2ms |
| EMI/RFI
Filter |
10dB
at 15 MHz, 50dB at 30MHz |
| Overload
Protection |
UPS
automatic shutdown if overload exceeds 110% of nominal for 60 seconds
and 130% for 3 seconds. |
| Unit
Input |
Fuse
for overload & short circuit protection |
| 10Base-T
Cable port |
Network
(UTP, RJ-45) compatible jacks |
| Short
Circuit |
UPS
output cut off immediately or input fuse protection |
| Safety
Conformance |
cUL,
TUV, CE, meet FCC |
| Surge
Protection |
Meet
IEEE 587 standard |
| Battery |
| Type |
Sealed
Maintenance Free Battery High efficiency GT technology |
| Backup
Time |
15
- 30 min. depending on load/model of UPS |
| Recharge
Time |
4
hours to 90% |
| Protection
|
Automatic
self-test & discharge protection, replace battery indicator. |
| Environment |
| Temperature |
0°
C to 48° C |
| Humidity |
0%
to 95% (non-condensing) |
| Elevation |
6000
meters max. Elevation |
| Audible
Operation |
<40dBA
(1 meter from surface) |
| Mechanical |
| Weight/net(kgs) |
13 |
15 |
15.2 |
15.6 |
30 |
| Dimension(WxHxD)
|
130x201x382 mm. |
170x214x448
mm. |