Request
More Information on this Model
|
|
|
|
|
| Series |
LCM |
| UPS
Type |
True Online with LCD Status Display, 3 Phase* |
| Power
Range |
6
KVA to 20 KVA |
|
 |
LCD display
front panel |
 |
Double
CPU control |
 |
Cold
start (DC power on) |
 |
True
online double conversion design |
 |
Pure
sinewave output less than 3% THD |
 |
Wide
input voltage range +/-27% of nominal |
 |
Versatile,
modular design provides flexibility during setup and service |
 |
Smart
RS-232 communication port |
 |
SNMP
management capabilty |
 |
Management
software compatible |
 |
Power
factor correction |
 |
Overload
& short-circuit protection |
 |
Load
and battery status indicator |
 |
Fan
speed auto control when load varies |
 |
Extended
backup time with battery pack |
 |
Advanced
battery management (ABM) |
 |
Battery
power & load meter display |
 |
Compact
size, light weight & low noise |
| Model
|
LCM6k |
LCM8k |
LCM10k |
LCM12k |
LCM10k3 |
LCM12k3 |
| Power
Range |
6000VA |
8000VA |
10KVA |
12KVA |
10KVA |
12KVA |
| Input |
| Voltage
|
170
~ 276V |
176~276V |
304~478V |
| Frequency |
50/60 HZ +/- 5% |
| Power
factor |
>=
0.97 |
>=0.95 |
| Phase |
Single
Phase |
3
Phase 4 Wire |
| Output |
| Voltage |
110/220
(1 § 3W adjustable)110/220 |
| Phase |
Single
Phase |
| Voltage
Regulation |
+/-
2% |
| Frequency |
50/60Hz
+/-0.5% |
| Frequency
Stability |
+/-
0.5% |
Efficiency
(AC to AC) |
>87% |
>85% |
| Total
Harmonic Distortion |
Less
than 3% at linear load |
| Power
Factor |
0.7
Lagging |
| Crest
Factor |
3:1 |
| Overload
Detection |
>105%
for 10 seconds |
| 130%
+/-10% for 300ms |
| Transfer |
| Power
Failure and Recovery |
0
ms |
| Overload
disappear |
Auto
transfer to UPS |
| Bypass |
0
ms |
| Alarm |
| Battery
Discharge |
The
first warning will every 4 seconds to indicate battery in use. The
second warning will beep every 1 second to signal battery low condition. |
| UPS
Fault |
Continuos
beeping sound |
| LCD
Indicators |
| Status
|
Indicate
line, bypass, iv, backup, fault, bat capacity, load capacity, I/P
voltage, I/P frequency, O/P voltage, inside temprature, fault status |
| Environment |
| Operating
Temprature |
10°C
to 40°C |
| Relative
Humidity |
20%
~ 90% (Non condensing) |
| Noise
Level |
<45dBA |
<55dBA |
<60dBA |
| Battery |
| DC
Voltage |
240V |
| Backup |
Full
Load |
7
Min |
15
Min |
10
Min |
7
Min |
10
Min |
7
Min |
| Half
Load |
19
min |
40
Min |
28
Min |
20
Min |
28
Min |
20
Min |
| Type |
Sealed
maintenance free |
| Protection |
Battery
low cut-off without draining any current |
| Recharge
Time |
About
10 Hours to 90 % after full discharge |
| Mechanical
|
| Dimensions
(WxDxH)mm |
260x555x700 |
340x640x980 |
| Weight
(Kg) |
114 |
250 |
| Other
Options |
| Remote
Panel |
LCD
Indication for the status of the rectifier, battery, inverter and
output load |
| Interface |
Supporst
both RS-232 & dry contact signal to provide power management &
dignostic functions including power status, battery low, schedule
UPS ON/OFF, battery/load level display and more. Compatible with Windows
NT, Novell, AS-400 and SNMP. |
|