Series RMS
UPS Type True Online Rack Mountable
Power Range 700 VA to 3KVA
-
Features
Double CPU Control
True Online double conversion design
Pure sine-wave output less than 3% THD
Wide input range +/- 27% of nominal
Smart RS-232 communication port
SNMP management capability
Management Software compatible
Power factor correction
Overload & short-circuit protection
Cold Start (DC power on)
Load and battery status indicator
Extended back up time with battery pack
Advanced battery management (ABM)
Versatile, modular design provides flexibilty during setup and service
Battery power & load meter display
Compact size, light weight & low noise
Fan speed auto control when loads varies
-
Product Specifications
Model RMS700 RMS1000 RMS1500 RMS2000 RMS3000
Power Rating 700VA 1000VA 1500VA 2000VA 3000VA
Input
Voltage 100V:76V~130, 110V :80V~138v, 115V:83.5V~140v, 120:87V~140V
208V:152~260V, 220V:160V~276V, 230V:167V~280V, 240V:174V~280V
Frequency 50Hz or 60Hz +/- 3hz
Phase Single Phase
Power Factor <=0.98
Output
Voltage 100/110/115/120V or 208/220/230/240V
Voltage Regulation +/- 2% (except MTS3000/110V +/- 3%)
Frequency 50 or 60Hz
Frequency Stability +/- 0.5%
Efficiency
(AC to AC)
>85%
Total Harmonic Distortion Less than 3% at linear load
Power Factor 0.7 Lagging
Slew Rate <1Hz/Sec
Overload Detection 105% for 10 seconds
130% +/- 10% for 300ms
Crest Factor 3:1
Transfer
Power Failure and Recovery 0 ms
Overload disappear Auto transfer to UPS
Alarm
Battery Discharge The first warning will every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition.
UPS Fault Continuos beeping sound
Environment
Operating Temprature 0°C to 40°C
Relative Humidity 0% ~ 95% (Non condensing)
Noise Level <45dB at 1 meter distance <52dB at 1 meter distance
Battery
Backup (Min) Full Load 5 7 5 9 7
Half Load 12 20 17 20 15
DC Voltage 24V 36V 48V 72V 96V
Type Sealed Maintenance Free
Protection Cut off without draining any current when battery low
Recharge Time About 8 hours to 90 % after fully discharged
Mechanical
Dimensions (WxDxH)mm 483x400x130 483x470x130
Weight (Kg) 21.1 23.5 26.1 27 31
Other Options
Interface Supporst both RS-232 & dry contact signal to provide power management & dignostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatible with Windows NT, Novell, AS-400 and SNMP.
-
-
Copyright © 2000, American Micronic Instruments, Inc., USA